30 SUNFAR C300
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code Name Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F5. 0 Multi-speed running mode
The first part of
LED(form right to
left):PLC setting
0:PLC is invalid. 1:PLC is valid.
2:PLC is conditional invalid.
The second part of
LED:Simple PLC running mode selection
0:Single loop mode
1:Single loop and stop mode
2:Continuous loop mode
3:Continuous loop and stop mode
4:Keep the end value
5:Keep the end value and stop mode
The third part of LED
0:Restart from the first stage freq.
1:Restart from running freq. which is
saved before running is break
2:Restart from setting freq. when
running is break.
The fourth part of LED:PLC save state
0:Non-save after power off
1:Save after power off
1 0000 ★
F5. 1 Multi-speed frequency 1 0.0 ~ the upper limit freq. 0.01 35.00
F5. 2 Multi-speed frequency 2 0.0 ~ the upper limit freq. 0.01 15.00
F5. 3 Multi-speed frequency 3 0.0 ~ the upper limit freq. 0.01 3.00
F5. 4 Multi-speed frequency 4 0.0 ~ the upper limit freq. 0.01 20.00
F5. 5 Multi-speed frequency 5 0.0 ~ the upper limit freq. 0.01 25.00
F5. 6 Multi-speed frequency 6 0.0 ~ the upper limit freq. 0.01 30.00
F5. 7 Multi-speed frequency 7 0.0 ~ the upper limit freq. 0.01 35.00
Multi-speed running parameter unit
F5.8 Multi-speed frequency 8 0.0 ~ the upper limit freq. 0.01 40.00