EasyManua.ls Logo

Sunfar C300 Series - Auxiliary Running Parameters: Braking and Acceleration Times; Multi-Speed Running Parameters: Mode and Frequency

Default Icon
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 SUNFAR C300
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code Name Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F5. 0 Multi-speed running mode
The first part of
LED(form right to
left)PLC setting
0PLC is invalid. 1PLC is valid.
2PLC is conditional invalid.
The second part of
LEDSimple PLC running mode selection
0Single loop mode
1Single loop and stop mode
2Continuous loop mode
3Continuous loop and stop mode
4Keep the end value
5Keep the end value and stop mode
The third part of LED
0Restart from the first stage freq.
1Restart from running freq. which is
saved before running is break
2Restart from setting freq. when
running is break.
The fourth part of LEDPLC save state
0Non-save after power off
1Save after power off
1 0000
F5. 1 Multi-speed frequency 1 0.0 ~ the upper limit freq. 0.01 35.00
F5. 2 Multi-speed frequency 2 0.0 ~ the upper limit freq. 0.01 15.00
F5. 3 Multi-speed frequency 3 0.0 ~ the upper limit freq. 0.01 3.00
F5. 4 Multi-speed frequency 4 0.0 ~ the upper limit freq. 0.01 20.00
F5. 5 Multi-speed frequency 5 0.0 ~ the upper limit freq. 0.01 25.00
F5. 6 Multi-speed frequency 6 0.0 ~ the upper limit freq. 0.01 30.00
F5. 7 Multi-speed frequency 7 0.0 ~ the upper limit freq. 0.01 35.00
Multi-speed running parameter unit
F5.8 Multi-speed frequency 8 0.0 ~ the upper limit freq. 0.01 40.00

Table of Contents

Related product manuals