EasyManuals Logo

Sunfar C300 Series User Manual

Default Icon
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
SUNFAR C300 31
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code Name Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F5. 9
Running time of
Multi-speed 1
0.06000 s 0.1 10.0
F5. 10
Running time of
Multi-speed 2
0.06000 s 0.1 10.0
F5. 11
Running time of
Multi-speed 3
0.06000 s 0.1 10.0
F5. 12
Running time of
Multi-speed 4
0.06000 s 0.1 10.0
F5. 13
Running time of
Multi-speed 5
0.06000 s 0.1 10.0
F5. 14
Running time of
Multi-speed 6
0.06000 s 0.1 10.0
F5.15
Running time of
Multi-speed 7
0.06000 s 0.1 10.0
F5.16
Running time of
Multi-speed 8
0.06000 s 0.1 10.0
F5.17
Running direction of PLC
multi-speed
The first part of LED(form right to left)
0Stage 1 FWD 1Stage 1 REV
The second part of LED
0Stage 2 FWD 1Stage 2 REV
The third part of LED
0Stage 3 FWD 1Stage 3 REV
The fourth part of LED
0Stage 4 FWD 1Stage 4 REV
1 0000
F5.18
Running direction of PLC
multi-speed
The first part of LED(form right to left)
0Stage 5 FWD 1Stage 5 REV
The second part of LED
0Stage 6 FWD 1Stage 6 REV
The third part of LED
0Stage 7 FWD 1Stage 7 REV
The fourth part of LED
0Stage 8 FWD 1Stage 8 REV
1 0000
Multi-speed running parameter unit
F5.19 Reserved

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sunfar C300 Series and is the answer not in the manual?

Sunfar C300 Series Specifications

General IconGeneral
BrandSunfar
ModelC300 Series
CategoryInverter
LanguageEnglish

Related product manuals