SUNFAR C300 31
C300 series of non-sensor current vector-control inverter manual
Parameters’
Types
Function Code Name Setting range
Minimum
Setting
Manufacture
Setting
Modify
Limit
F5. 9
Running time of
Multi-speed 1
0.0~6000 s 0.1 10.0
F5. 10
Running time of
Multi-speed 2
0.0~6000 s 0.1 10.0
F5. 11
Running time of
Multi-speed 3
0.0~6000 s 0.1 10.0
F5. 12
Running time of
Multi-speed 4
0.0~6000 s 0.1 10.0
F5. 13
Running time of
Multi-speed 5
0.0~6000 s 0.1 10.0
F5. 14
Running time of
Multi-speed 6
0.0~6000 s 0.1 10.0
F5.15
Running time of
Multi-speed 7
0.0~6000 s 0.1 10.0
F5.16
Running time of
Multi-speed 8
0.0~6000 s 0.1 10.0
F5.17
Running direction of PLC
multi-speed
The first part of LED(form right to left):
0:Stage 1 FWD 1:Stage 1 REV
The second part of LED:
0:Stage 2 FWD 1:Stage 2 REV
The third part of LED:
0:Stage 3 FWD 1:Stage 3 REV
The fourth part of LED:
0:Stage 4 FWD 1:Stage 4 REV
1 0000
F5.18
Running direction of PLC
multi-speed
The first part of LED(form right to left):
0:Stage 5 FWD 1:Stage 5 REV
The second part of LED:
0:Stage 6 FWD 1:Stage 6 REV
The third part of LED:
0:Stage 7 FWD 1:Stage 7 REV
The fourth part of LED:
0:Stage 8 FWD 1:Stage 8 REV
1 0000
Multi-speed running parameter unit
F5.19 Reserved