15
It is recommended to use the communication module from SUNGROW. Using a
device from other companies may lead to communication failure or other unex-
pected damage.
The inverter can provide export control but will require the use of a external smart meter.
The export control functionality has not been tested to AS/NZS 4777.2:2020.
Protection Function
The protective functions are integrated in the inverter, including anti-island protection, LVRT/
ZVRT, DC reversed polarity protection, AC short circuit protection, leakage current protec-
tion, DC overvoltage/overcurrent protection, etc.
PID recovery
The PID effect (Potential Induced Degradation) of PV modules will cause serious damage to
generated output and yield, which can be avoided or recovered by PID recovery function.
For positive voltage scheme, after the PID is enabled, the voltage to ground of all PV
strings is greater than 0, and therefore the PV string-to-ground voltage is a positive value.
For negative voltage scheme, after the PID is enabled, the voltage to ground of all PV
strings is lower than 0, and therefore the PV string-to-ground voltage is a negative value.
User Manual 2 Product Description

Table of Contents

Other manuals for Sungrow SG50CX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX and is the answer not in the manual?

Sungrow SG50CX Specifications

General IconGeneral
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of MPPTs4
Rated AC Output Power50 kW
Max. AC Output Current76 A
Frequency50 Hz / 60 Hz
Efficiency98.6%
Start Voltage200 V
Number of DC Inputs per MPPT2
Max. AC Apparent Power55 kVA
AC Voltage Range310 V - 480 V
Power Factor at Rated Power1
Adjustable Power Factor Range0.8 leading - 0.8 lagging
THDi< 3%
DC SwitchYes
AC Surge ProtectionType II
DC Surge ProtectionType II
Protection ClassI
Cooling MethodSmart forced air cooling
Protection DegreeIP66
Protection LevelIP66
Operating Temperature Range-25°C to +60°C
Humidity0-100%
AC Output Voltage3 / N / PE, 220 V / 380 V, 230 V / 400 V