cold mixed together greatly increases cleaning efficiency and also customer
experience. The following is required:
•Hot and cold water service is required with a minimum of 40 psi (276 kPa) and a
maximum of 100 psi (689 kPa), and capable of 8 GPM (30 LPM). The cold water
supply needs to be within 4 feet (122 cm) of the back of the Versa6SDPro
TM
. A
standard U.S. male garden hose fitting is required with a shut-off valve.
•The drain service needs to be within four feet of the back of the Versa6SDPro
TM.
Thedrain should be terminated with a standard male garden hose fitting and a
shutoff valve for ease of disconnection. The Versa6SDPro
TM
is equipped with a
fullyautomatic fluid discharge system. This system is capable of overcoming 12
feet(335cm) of head pressure. A minimum drainpipe diameter of 5/8” (16 mm) is
required. Drainage should be directed to the sewer system.
•All plumbing work must be completed according to local building codes.