1. Remove air cap, collar and nozzle tip
a. Check nozzle tip for debris and clean as necessary
b. If still not even, contact Sunless, Inc. Technical
Support
c. Solution reservoir check valve may be stuck or defective
ii. Contact Sunless, Inc. Technical Support
D. Solution results darker on one side or the other
a. Run same tests as C(b)
E. Tanning results are speckling or blotchy
a. Check for and repair any air leaks at:
i. Air blower manifold
ii. Air hoses
iii. Air hose connections
b. Nozzle tip loose
i. Tighten nozzle tip
c. Air cap and/or collar loose
i. Tighten air cap and collar
d. Clogged or broken check valves at inlet to nozzle block
i. Run purge solution through system and re-check
e. Dirty air caps
i. Clean and replace
f. Solution Volume Per Pass set too low
i. Check Volume per pass in Session Parameters. If too low, adjust
the values or reset to default factory settings.
g. Nozzle Blower Level set too low
i. Check Nozzle Blower Level in Session Parameters. If too low,
adjust the values or reset to default factory settings.
F. No solution coming out
a. Reservoir empty
i. Out of solution
1. Add new solution container
b. Solution pump not working
i. Contact Sunless, Inc. Technical Support
c. Section of tubing clogged.
i. Contact Sunless, Inc. Technical Support
BLOWER SYSTEM ISSUES (AIR AND HEAT)
A. Blowers not coming on
a. Contact Sunless, Inc. Technical Support
B. Heaters not working
a. One heater not working
i. Defective Heater or poor connection
1. Contact Sunless, Inc. Technical Support
b. All heaters not working
i. 3 defective heaters or connections
1. Contact Sunless, Inc. Technical Support
Section 8! Troubleshooting