EasyManua.ls Logo

SunStar SPS/A-3020 5030 SERIES - Page 65

SunStar SPS/A-3020 5030 SERIES
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
D.
Check if the values of X0rg and Y0rg are changed
when the feed plate passes on origin making it
move manually to X and Y shaft.
Confirm if the value of ThSen is changed when
you release a take up lever spring after pulling
slightly.
E. If you want to finish Input0 test, press ESC key.
If you want to finish test menu, press ESC key.
F.
Back to the initial screen by pressing ESC key.
XPSen 1 X0rg 1
XMSen 1 YPSen 0
Y0rg 1 ThSen 0
A.
Press MODE key.
B.
After moving to “4. Machine Test”by using
direction keys , press ENTER key.
C.
After moving to “8. Input 1 Test”by using direction
keys , press ENTER key.
D.
Check if the value of EM_SW is changed when
we press EMERGENCY STOP switch.
Check if the value of FF_SW is changed when
we step on the right pedal switch or ST_SW
when we step on the left pedal switch.
E.
If you want to finish Input1 test, press ESC key.
If you want to finish test menu, press ESC key.
F.
Back to the initial screen by pressing ESC key.
<< Main Menu >>
4. Machine Test
5. Pattern List
6. EMB Call
<< Test Menu >>
8.Input1 Test
9.Input2 Test
10.XY-Jog Test
MMErr 1 Sync 0
EM_SW 1 ST_SW 1
FF_SW 1 FFLSW 1
TS_SW 1
(9) Input 1 Test
It is to test if peripheral switch input among all input signals works properly.
(10) Input 2 Test
It is to test if auxiliary input signal works properly.

Table of Contents