35
No. Sign Range Default Description REG
312
Fall Auto
Correction
Interval
1~99 3
Interval of Fall Value Auto Correction N
After Deviation Alarm Count reached to N, Fall
Value will be corrected automatically.
40325
313
Fall Auto
Correction Range
1
~60000
50
Fall Value Auto Correction Range
If the absolute value of deviation exceeds this
range, it will not be used for the calculation of Fall
Correction Value.
40327
314
Fall Auto
Correction Ratio
0~2 1
Fall Value Auto Correction Ratio [%]
0: 25%; 1: 50%; 2: 100%
New Fall Value = Original Fall Value + Deviation
Value × Fall Value Auto Correction Ratio.
Deviation Value = Final Feeding Weight - Target
Value.
40329
315 Unused 0 0 Unused 40331
316 Unused 0 0 Unused 40333
317 Dumping Mode 0~3 2
Dumping Mode
0: Separately [1/2/3/4]
[Dump after one material has been fed]
1: Together [1&2&3&4]
[Dump after all materials have been fed]
2: In Order [1-2-3-4]
[Dump in order [1-2-3-4] after all materials have
been fed]
3: In Order [4-3-2-1]
[Dump in order [4-3-2-1] after all materials have
been fed]
40335