38
No. Sign Range Default Description REG
408
T8 Mixing Time
Before Mix-bin
Dumps
0~9999 0
T8 Mixing Time Before Mix-bin Dumps [s]
Single-scale Mode:
Set value = 0: The Mixer in the weighing hopper
[mixing bin] will not work before auto-dumping.
Set value > 0: The Mixer in the weighing hopper
[mixing bin] will work for time the
T8 before
auto-dumping.
Four-scale Mode:
Set value = 0: There is not a mixing bin in the
batching system.
Set value > 0: There is a mixing bin with dumping
gate and mixer in the batching system. The mixer
will work for time the T8 before auto-dumping.
40417
409
T9 Delay After
Mixing Conveyor
Ready
0~999 3
T9 Delay After Mixing Conveyor Ready [s]
With the DI signal ‘Mixing Conveyor Ready’ being
used, its allowed to auto-dump
materials to the
mixing conveyor
only after the DI turned on and
then the time T9 delayed for ensuring that the
mixing conveyor has run normally before dumping.
40419
410
T10 Delay to
Normal-stop
Conveyor
0~999 5
T10 Delay to Normal-stop Conveyor [s]
It’s used for the batching systems normal-stopping.
After the auto-dumping process ended, the mixing
conveyor
will keep running for the time T10 for all
the materials have been conveyed before stopping.
Four-scale Mode: Only after
the mixing
conveyor stopped, the mixing bins dumping gate
will be closed automatically.
40421