When fast feed start or change from fast feed to slow feed, the suddenly material impact
change will cause the scale signal bigger than the actual weight. To avoid capturing wrong
weight data, the terminal do not read weight signal during the CIT time (F6.3.2).
Testing time delayTTC
To avoid any disturbance the terminal will delay a few times after feed over then record
material data. The time can be set at F6.3.3.
Delay after Dump time.TDC
On each dump sequence, when the material in the hopper are Dump under zero range, this
timer is triggered and the dump door will close on the timer expired. The time is set at F6.3.4.