14
5.4 Keypad
Keypad operation in gross display mode.
Upper window display gross weight, lower window display 0”Net cursor be off.
Keypad
Function
Operation instruction
Note
Tare
The terminal executes tare operation under below
conditions:
1) The terminal is in idle mode (no running procedure)
2) Keypad tare is enabled (parameter F2.2=1)
3) The weight signal is stable (cursor STAB. Is lit)
Preset Tare (F2.2=2):
Press ENTER key to fetch current displayed weight into
lower window.
Press ENTER again to accept current weight as preset
tare weight.
Or press [SELECT] and [TARE] key to set new preset
tare weight.
zero
The terminal executes tare operation under below
conditions:
1) The terminal is in idle mode (no running procedure)
2) The gross weight is under zero range.
3) The weight signal is stable (cursor STAB. Is lit)
The terminal responses [
NO
] if any condition is not
fulfilled.
Select
Press “select to change to every menu, it does not
influence batching process when changing menu.
enter
Print (F3.1=1 or 2). Condition:
1) The terminal displays gross or net weight.
2) The weight signal is stable.
If the weight is in motion terminal will response [NO].
Keypad operation in net display mode
Upper window displays net weight, lower window displays tare weight and Net cursor is lit.
Keypad
Function
Operation instruction
Note
Clear
tare
Press this key to clear stored tare weight and the
displayed weight return to gross mode if no batch
procedure is running.
select
Press “select to change to every menu, it does not
influence batching process when changing menu.
enter
Print (F3.1=1 or 2). Condition:
3) The terminal displays gross or net weight.
4) The weight signal is stable.
If the weight is in motion terminal will response [
NO
].