Chapter 8 Output Module Reference Data
E1/2048 kHz Output Module
202 SSU-2000e Users Guide 12713140-002-2 Revision E – October 2006
To enable the squelching feature, you must provision a “threshold” PQL value using
the OUTPUT command (for ICS mode) or the SET-PRMTR-OUTE12048 command
(for TL1 mode). The syntax for each command is shown below. A threshold PQL
value of zero disables the squelch function. Threshold PQL values above zero
enable the squelch function; when the system PQL is greater than the threshold
PQL, the output is squelched.
For example, you can provision output ports 1 through 5 for a threshold PQL of 3
and you can disable squelching for ports 6 through 20 (PQL is set to 0). In this
example, if the system PQL is 1, 2, or 3, ports 1 through 20 generate outputs. If the
system PQL changes to 4 or higher, outputs on ports 1 through 5 are squelched
(turned off) and ports 6 through 20 continue to generate outputs. The response from
the Output Status command appears as shown in the following example.
Copyright 1997-2005, Symmetricom
SSU_2000->out 2A10
2005-09-06T19:43:03Z ID: SSU2000, Name: SSU_2000
Module Name: Output E1/2048
OUT STATUS Clk Clk Stat Port Status 1 1 1 1 1 1 1 1 1 1 2
Loc# Type Sta Sel A B C D Redt PQL 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
---- ----- --- --- -------- ---- --- ----------------------------------------
2A10 E12M Ok B / / / / 4 / / / / / / / / / / / / / / / / / / / /
OUTPUT SETUP -------- E1 -------
Loc# Type Bypass ZS SIG CRC SSM BIT
---- ----- ------ --- --- --- --- ---
2A10 E12M On On CAS On On 8
Signal:
P[ 1]= E1, P[ 2]= E1, P[ 3]= E1, P[ 4]= E1, P[ 5]= E1,
P[ 6]= E1, P[ 7]= E1, P[ 8]= E1, P[ 9]= E1, P[10]= E1,
P[11]= E1, P[12]= E1, P[13]= E1, P[14]= E1, P[15]= E1,
P[16]= E1, P[17]= E1, P[18]= E1, P[19]= E1, P[20]= E1,
Squelch:
P[ 1]= 0, P[ 2]= 0, P[ 3]= 0, P[ 4]= 0, P[ 5]= 0,
P[ 6]= 0, P[ 7]= 0, P[ 8]= 0, P[ 9]= 0, P[10]= 0,
P[11]= 0, P[12]= 0, P[13]= 0, P[14]= 0, P[15]= 0,
P[16]= 0, P[17]= 0, P[18]= 0, P[19]= 0, P[20]= 0,
SSU_2000->
When the System PQL transitions to a PQL that crosses the user-defined Output-
Squelching PQL threshold, the SSU generates a major alarm. The alarm message
for Squelch indicates which port(s) are in alarm due to the PQL threshold being
crossed. In the example Alarm message below, Port 20 of the E1/2048 kHz module
is in alarm.
2002-12-12T10:25:26 2A10 Maj Squelch, Below Prov, 00001
A five-digit hexadecimal number (consisting of 20 bits) at the end of the alarm
message identifies the affected port(s). Each digit represents four of the 20 ports on
the module; the first digit represents ports 1 through 4, the second digit represents
ports 5 through 8, and so on, as shown in Figure 8-7.

Table of Contents

Other manuals for Symmetricom SSU-2000e

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000e and is the answer not in the manual?

Symmetricom SSU-2000e Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000e
CategoryPower Supply
LanguageEnglish

Related product manuals