REPORT ALARM (Contd)
condtype: AIS = alarm indication signal
FA = fuse alarm
FRNGSYNC = clock is in the freerunning mode
FSTSYNC = clock is in the fast-converge mode
HLDOVRSYNC = clock is in the holdover mode
INT = card has failed
LOS = loss of signal
SFI = loss of stratum input to MRC
SLTMSIG = input references are unlocked
SYNC = input reference has failed
SYNCCLK = output port has failed
SYNCPRI = loss of all primary timing references
SYNCSEC = loss of all secondary timing references
TBPV = threshold violation for BPVs
TCRC = threshold violation for CRC errors
TFFREQ = threshold violation for fractional frequency
TMTIE1 = threshold for MTIE 1 second has been exceeded
TMTIE4 = threshold for MTIE 4 seconds has been exceeded
TMTIE16 = threshold for MTIE 16 seconds has been exceeded
TMTIE64 = threshold for MTIE 64 seconds has been exceeded
TMTIE128 = threshold for MTIE 128 seconds has been exceeded
TMTIE512 = threshold for MTIE 512 seconds has been exceeded
TMTIE900 = threshold for MTIE 900 seconds has been exceeded
TOOF = threshold for OOFs has been exceeded
TTVAR1 = threshold for TVAR 1 second has been exceeded
TTVAR4 = threshold for TVAR 4 seconds has been exceeded
TTVAR16 = threshold for TVAR 16 seconds has been exceeded
TTVAR64 = threshold for TVAR 64 seconds has been exceeded
TTVAR128 = threshold for TVAR 128 seconds has been exceeded
For GTI only:
FA = fuse A
FB = fuse B
GPSLOS = GPS loss of signal
GPSINVLD = GPS timing is invalid
GTIOUTFLT = primary rate output of the GTI has been faulted
GTIFAILx = hard failure, where x = 1 through 3. The numbers 1-3
are diagnostic codes for field service/engineering use
only
OSCALOS = signal energy on OSC A input
OSCBLOS = signal energy on OSC B input
GTRPWR = power supply has been faulted by a short, an open, or
equipment failure
GTRCOMM = The GTI has timed out waiting for a status message
from the GTR
GTRFAILx = hard failure, where x = 1 through 5. The numbers 1-5
are diagnostic codes for field service/engineering use
only
srveff: SA = service-affecting condition
NSA = nonservice-affecting condition

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals