Issue 3: Mar 96 TMSL 097-45018-02
Page 57
REPORT ALARM (Contd)
conddescr: ALARM INDICATION = received alarm indication
SIGNAL RECEIVED
CARD FAIL = card has failed
CLOCK ACTIVE = clock is active
CLOCK FREERUNNING = clock is in the freerunning mode
CLOCK IN HOLDOVER = clock is in the holdover mode
CLOCK NOT CONVERGED = clock is not locked to the input signal
DISCIPLINING REFERENCE = timing input has switched to another
SWITCHED reference
EXPANSION MAJOR = expansion shelf has a major alarm
EXPANSION MINOR = expansion shelf has a minor alarm
FRAMER FAILURE = framing
FUSE OR POWER FAIL = fuse or power at DCD system has failed
INPUT OUT OF TOLERANCE = input signal is out of the clock unitÕs
pull-in range
INPUT ACTIVE = input signal is active
LOSS OF SIGNAL = signal is lost
LOSS OF ALL PRIMARY = all primary timing input references have
TIMING INPUT been lost
REFERENCES
OUTPUT SYNC PORT FAIL = output port on an output card has failed
SYNC INPUTS UNLOCKED = synchronization inputs are unlocked
SYNC INPUT FAILED = input reference signal input has failed
SYNC SYSTEM FAIL = entire system has failed
THRESHOLD VIOLATION = bipolar violation threshold has been
FOR BPV exceeded
THRESHOLD VIOLATION = cyclic redundancy check threshold has
FOR CRC been exceeded
THRESHOLD VIOLATION = fractional frequency threshold has been
FOR FFREQ exceeded
THRESHOLD VIOLATION = an MTIE threshold has been exceeded
FOR MTIE OBSERVATION
THRESHOLD VIOLATION FOR = threshold for MTIE 1-second
MTIE1 OBSERVATION observation has been exceeded
THRESHOLD VIOLATION = threshold for MTIE 4-second
FOR MTIE4 OBSERVATION observation has been exceeded
THRESHOLD VIOLATION = threshold for MTIE 16-second
FOR MTIE16 OBSERVATION observation has been exceeded
THRESHOLD VIOLATION = threshold for MTIE 64-second
FOR MTIE64 OBSERVATION observation has been exceeded
THRESHOLD VIOLATION = threshold for MTIE 128-second
FOR MTIE128 OBSERVATION observation has been exceeded
THRESHOLD VIOLATION = threshold for MTIE 512-second
FOR MTIE512 OBSERVATION observation has been exceeded
THRESHOLD VIOLATION = threshold for MTIE 900-second
FOR MTIE900 OBSERVATION observation has been exceeded
THRESHOLD VIOLATION = out-of-frame threshold has been exceeded
FOR OOF

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals