TMSL 097-45018-02 Issue 3: Mar 96
Page 84
RETRIEVE PERFORMANCE MONITORING T1 (Contd)
valdty: COMPLD = data was accumulated over the entire 15-minute time period
PRTL = data was accumulated over part of the 15-minute time period
NA = data not available
The following response occurs if analog is the input:
<sid> <date> <time>
M <ctag> COMPLD
[ "<aid>:<montype>,-1,,,,,,"
"<aid>:<montype>,-1,,,,,,"
;
Examples:
The following response occurs if E1 is the input:
TELECOMSOLUTIONS 96-02-08 19:35:35
M 177 COMPLD
"MRC-1-4:OOF,1,COMPLD,,,,15-MIN,18-45"
"MRC-1-4:OOF,3,COMPLD,,,,15-MIN,19-00"
"MRC-1-4:OOF,0,COMPLD,,,,15-MIN,19-15"
"MRC-1-4:OOF,1,PRTL,,,,15-MIN,19-30"
;
This example, the response to command 141, shows that MRC A, span 4, had 1 out-of-frame (OOF)
errors in the 15-minute period ending at 6:45 pm, 3 OOFs in the period ending 7 pm, and 0 in the
current 15-minute time period. The current time period is not complete, and is labeled ÒpartialÓ.
The following response occurs if analog is the input:
TELECOMSOLUTIONS 96-02-08 19:35:35
M 177 COMPLD
"MRC-1-4:OOF,-1,COMPLD,,,,15-MIN,18-45"
"MRC-1-4:OOF,-1,COMPLD,,,,15-MIN,19-00"
"MRC-1-4:OOF,-1,COMPLD,,,,15-MIN,19-15"
"MRC-1-4:OOF,-1,PRTL,,,,15-MIN,19-30"
;
This example, the response to command 141, shows that MRC A, span 4, had -1 out-of-frame (OOF)
errors in the 15-minute period ending at 6:45 pm, -1 OOFs in the period ending 7 pm, and -1 in the
current 15-minute time period. The current time period is not complete, and is labeled ÒpartialÓ.
;