Issue 3: Mar 96 TMSL 097-45018-02
Page 83
RETRIEVE PERFORMANCE MONITORING T1 (Contd)
Note: Counts for each 15-minute time period from the specified period to the current are retrieved. If
the date is not specified, the time period is assumed to be in the last 24 hours. If the previous day
is specified, only starting times between midnight (00:00) and 24 hours ago are accepted. If the
current day is specified, only starting times between midnight (00:00) and the current time are
accepted. In all accepted cases, all data to the current time are retrieved.
Examples:
Note: For all the following examples, assume the current date and time are 06-23 and 19-37, or June
23 and 7:37 pm. The current time period is 19-30, the time period between 7:30 pm and 7:45 pm.
RTRV-PM-T1::MRC-1-4:141::OOF,,,,,,18-45;
The above example, tagged as command 141, retrieves and displays the out-of-frame performance
monitoring data for span 4 on MRC-A. Data is displayed for each 15-minute count since 6:45 pm
today.
RTRV-PM-T1::MRC-1-4:173::OOF,,,,,06-22,18-45;
The above example, tagged as command 173, is invalid. The time is more than 24 hours ago.
RTRV-PM-T1::MRC-1-4:174::OOF,,,,,,21-45;
The above example, tagged as command 174, retrieves and displays the out-of-frame performance
monitoring data for span 4 on MRC-A. Data is displayed for each 15-minute count since 9:45 pm
yesterday, which is the only 21-45 in the last 24-hour period. The result is the same if yesterdayÕs
date is specified.
RTRV-PM-T1::MRC-1-4:175::OOF,,,,,06-23,21-45;
The above example, tagged as command 175, is invalid. 9:45 pm today has not arrived yet.
RTRV-PM-T1::PSM-1-4:176::TOTALSLIP,,,,,1-DAY::;
The above example, tagged as command 176, retrieves and displays the total number of slips for
span 4 on PSM-A for the past 24-hour period.
COMPLETED RESPONSE
The following response occurs if E1 is the input:
<sid> <date> <time>
M <ctag> COMPLD
[ "<aid>:<montype>,<monval>,<valdty>,,,,15-MIN,<montm>,”] ...
"<aid>:<montype>,<monval>,<valdty>,,,,15-MIN,<montm>,”
;

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals