78 Reciter Fault Finding TB8100 Service Manual
© Tait Electronics Limited September 2006
7. Select Monitor > Monitoring > Channel and check that the reciter
is set to the correct channel. If it is, go to Step 8. If it is not, proceed
as follows:
Select Configure > Base Station > Channel Profiles and check
that the reciter is configured correctly.
Select Configure > Base Station > System Interface and check
that the settings in the Channel selection area are correct. If
external channel selection is enabled, check that no external
equipment (e.g. CTU) is selecting an invalid channel, as this will
result in a “channel invalid” alarm.
make sure that it does not interfere with the operation of the
reciter
Select Configure > Base Station > General and check that the
default channel is the correct channel required.
Check that the digital input switches on the CTU are set correctly.
8. Select Alarms > Current Alarm Status and check for alarms. If there
are alarms, go to Task 3
. If there are no alarms, go to “Visual
Inspection” on page 82.
Note Select Alarms > Reported Alarms to check the alarm history. The
alarm history may indicate which part of the reciter needs further
investigation. You can save these details to a file if required. Note
that the alarm history is erased when the reciter is powered down.

Table of Contents

Other manuals for Tait TB8100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tait TB8100 and is the answer not in the manual?

Tait TB8100 Specifications

General IconGeneral
BrandTait
ModelTB8100
CategoryAccessories
LanguageEnglish

Related product manuals