GTS Technical Manual
14. March 2014 Edition: V1.00/2014 5-19
Copyright © 2014, Diversey Care
05.17.10 vacuum unit & squeegee - vacuum motor - 30_45_V1.00.fm
5.4 Vacuum unit & squeegee
5.4.1 Removing of vacuum motor
Picture 30: Vacuum motor
Open fresh water tank according to chapter REMOVING OF FRESH
WATER TANK ASSEMBLY.
Lift the vacuum motor (30:05/104, 45:06/104) with all the seals
and absorber out of the chassis (30:03/105, 45:04/105).
Disconnect vacuum motor wires at the connection block (30:05/
127, 45:06/127).
Remove noise absorbers (30:05/101, 45:06/101) and (30:05/
107, 45:06/107), covers (30:05/102, 45:06/102) and (30:05/
106, 45:06/106), seals (30:05/103, 45:06/103) and (30:05/
105, 45:06/105).