62
MD 5.1
Limiter
The Limiter page is divided into three Sub-pages. One
coveringtheSoftclipsection,onefortheFullRangeLimiter
andonefortheLFELimiter.
Generic parameters in this algorithm:
Meter Zoom
Press Meter Zoom to decrease meter range and have a
more accurate metering.
Bypass Limiter
PresstoBypasstheLimitersectionofthe5.1algorithm.
Soft Clip page
Softclip
Full Range Softclip
Range: -6dB to Off
Softclipper Threshold setting after the Compressor for the
five multiband channels. Threshold is always relative to
0dBFS(NottheReferenceLevel).
LFE Softclip
Range: -6dB to Off
SoftclipperThresholdsettingfortheLFEchannelonly.
Full Limit. page
Threshold
Range: -12dB to Off
-6 to OdB in 0.1dB increments
-12to-6in0.5dBincrements
Brickwalllimiterforthefivemultibandchannels.Threshold
isalwaysrelativeto0dBFS.LEDoneachOutputmeter
indicates when Limiter is active.
Release
Range: 0.01 to 1.00 seconds
Release time for the Limiter.
Ceiling
Range: -0.10dB to 0dB
Fine-tuningparametersettingtheCeilingfortheLimiter.
The Ceiling parameter prevents the Output signal
fromexceedingtheadjustedLimiterThreshold.It
canbeusedto“hide”overloadstodownstream
equipment, but it does not remove the distortion
associated with an over.
LFE Limiter page
LFE Limiter
Threshold
Range:-12to+3dB
-6to+3in0.1dBincrements
-12to-6in0.5dBincrements
BrickwalllimiterfortheLFEchannel.Thresholdisalways
relativeto0dBFS.LEDoneachOutputmeterindicates
when limiter is active.
Release
Range: 0.01 to 1.00 seconds
Release time for the Limiter.
Ceiling
Range: 0 to -0.10dB in 0.01dB steps.
Fine-tuningparametersettingtheCeilingfortheLimiter.
The Ceiling parameter prevents the Output signal
fromexceedingtheadjustedLimiterThreshold.It
canbeusedto“hide”overloadstodownstream
equipment, but it does not remove the distortion
associated with an over.