Page #16 background imageLoading...
Page #16 background image
16
www.tcsmeters.com
Total Control Systems
TCS 3000 Installation
Installaon Procedure — Float Electronic Air Eliminator
Installaon Procedure:
1. Locate the air eliminator oat wiring on the metering system.
2. Install the cable gland into the back of the TCS 3000 register
and ghten into the housing.
3. Run the air eliminator oat wiring through the cable gland.
Wire the air eliminator oat into the Air Eliminator (AIR
ELIMINAT.) terminal on the board. Leave a small amount of
slack on the wiring.
4. Compress the cable gland on the TCS3000 register unl it is
snug on the air eliminator oat wiring.
5. Locate the air eliminator solenoid wiring on the metering
system.
6. Install the cable gland into the back of the TCS 3000 register
and ghten into the housing.
7. Run the air eliminator solenoid wiring through the cable
gland. Wire the air eliminator solenoid into the Auxiliary Re-
lay 2 (AUX 2) on the terminal board. Leave a small amount of
slack on the wiring.
8. Compress the cable gland on the TCS 3000 register unl it is
snug on the air eliminator solenoid wiring.
NOTE: Do not run mulple cables through a single cable
Air Eliminator Solenoid
Air Eliminator Float Wiring
RED
BLACK
1/4” NPT Exhaust Vent