40
www.tcsmeters.com
Total Control Systems
TCS 3000 Installation
Installaon Procedure — Replacement Register Front Cover
HINGE PIN ALLEN SCREW
SET SCREW
GROUND CABLE
50 PIN RIBBON
POWER RIBBON
FRONT COVER REPLACEMENT
SOCKET SCREW
HINGE PIN ALLEN SCREW
Installaon Procedure:
1. Unlatch the 50 Pin Communicaon and the Power ribbon cables from the front cover assembly.
2. Remove the grounding strap from the front cover assembly using a Philips screw driver.
3. Remove two Set Screws from the rear housing of the register hinges using a 3 mm Allen Wrench.
4. Remove the two Hinge Pin Allen Screws from the top and boom of the front cover assembly. Use a 2 mm Allen
Wrench for removal.
5. Once the replacement front cover computer is received, carefully remove the unit from the an-stac plasc bag
and do not dispose of the original packaging materials.
6. Reassemble the replacement front cover computer assembly to the rear housing with the Hinge Pin Allen Screws
and Set Screws.
7. Insert the 50 Pin Communicaon and Power ribbon cables and fastening the grounding cable.
8. Insert the front cover assembly in the an-stac bag and carefully place back into the original box packaging.
NOTE: Packing instrucons are within the original box.
9. Before shipping back to Total Control Systems, be sure to have a Returns Goods Authorizaon enclosed within the
packaging.
REQUIRED TOOLS:
2 mm Allen Wrench
3 mm Allen Wrench
5 mm Allen Wrench
Philips Screw Driver