4
www.tcsmeters.com Total Control Systems 4
TCS 3000 Installation
ELECTRICAL
Power 12 — 24 VDC INPUT
Current 1.4 Amps
Solid State Relays 12/24 Vdc; Passive Solid State
INTERNAL PULSER
Pulse Rao 100:1 PPR; Quadrature
Power 5 Vdc
Hertz 0 — 5000 Hz
EXTERNAL PULSE INPUT
Type Single or Dual Channel (Quadrature)
Power 5 Vdc
ENCLOSURE
Aluminum die cast with epoxy powder coat
Rangs UL/cUL Class 1, Division 2, Group C + D Hazardous Locaons
IP 66 / NEMA 4
Temperature Range - 40 F to 158 F (-40 C to 70 C)
Connecon Ports: Ten (10) 1/2” NPT UL/cUL threaded connecon ports
Oponal ten (10) M20 ATEX threaded connecon ports
Calibraon Seal Opcal switch, password and mechanical seal
Introducon
The TCS 3000 register is a fully integrated custody transfer ow computer that will control all vehicle delivery opera-
ons. The Open Soware Architecture provides the opon of a simple “Pump & Print” delivery or a custom measure-
ment soluon. The TCS 3000 features a 4.5”x 3.5” full color VGA display screen, mulple delivery screens and a backlit
alpha-numeric keypad for the user interface. Available in exible mounng conguraons of 75 or 90 degree displays
for meter mounng, and a remote mounng.
As an ow computer with open soware architecture, there will always be a need to add features to the register as the
industry applicaons evolve. Therefore please be reminded to contact the factory for periodic updates.
The TCS 3000 electronic register is a fully integrated ow computer that will control all delivery operaons. The modu-
lar design and open soware architecture provide you with a tailored system that is expandable for future needs. The
TCS 3000 features a large easy view VGA screen, alpha-numeric keypad and open printer interface for simple “Pump
and Print” deliveries. Soware features oer complete exibility of delivery screen informaon with preset, price/tax,
customizable cket format and password protecon.
Oponal GPS, Bluetooth, Wi-Fi and Cellular capability enables the TCS 3000 to improve your product security and ease
access to your delivery data to reduce your operaon costs. Many addional features are available (mulple product
delivery, addive injecon, density/temperature correcon, mulple valve & pump control, etc.) to enhance your
measurement soluon.
This manual will help guide you with the setup conrmaon and calibraon of the register. Addional informaon will
be provided for wiring instrucon and auxiliary devices to integrate into the register.
System Specicaons