TCS 3000 Installation
Installaon Procedure — 1-Stage Security Valve
Installaon Procedure:
1. Using the bolts and gasket provided, install the 655 Diaphragm or
755 Piston Valve on the outlet (downstream) side of the meter.
2. Wire the solenoid valve to Solenoid 2 (S2) for a Single Stage oper-
aon
3. Once the solenoid is wired, run the corresponding wire as pic-
tured using a minimum of 18 gauge shielded cable into the back
of the TCS 3000 register.
4. Insert the solenoid wiring into the cable gland. Wire the solenoid
into the correct solenoid locaon on the terminal board. Leave a
small amount of slack on the wiring.
5. Compress the cable gland on the TCS3000 register unl it is snug
on the solenoid wire.
655-21 Diaphragm 2” Valve
755-21 Piston 2” Valve
755-31 Diaphragm 3” Valve
*When Calibrang the Unit Set Up Valve Type as 1101*
S2
S2