122
STATus:OPERation:ENABle <NR1>
Function Sets the value of the Operational Condition Group Enable register. This
register is a mask for enabling specific bits from the Condition register to
the Event register. Refer to STATus:OPERation[:EVENt]? command for the
complete list of the registers that can be masked.
STATus:QUEStionable[:EVENt]?
Query Returns the value of the Questionable Condition Group Event register. This is a read-
only register.
The value is according to the Questionable Condition Group Condition register and
Questionable Condition Group Enable register.
Events are updated as transition from 0 to 1. Reading the register clears it.
Bit configuration of the Questionable Condition Group Event register is as follows:
Position
Value
Name
15
-
-
14
16384
POFF
13
-
-
12
-
-
11
2048
GERR
10
1024
PACK
9
512
UVP
8
256
ENA
POFF – Power OFF.
Set to “1” when the Power Supply
Power Switch is OFF.
GERR – General Error.
Unrecoverable system fault. Recycle
AC input.
PACK – Parallel Acknowledge.
Acknowledge new parallel system.
Refer to section 6.9.
UVP – Under Voltage Protection.
Set to “1” when Under Voltage
Protection fault occurs.
ENA – Enable.
Set to “1” when Enable fault occurs.
ILC – Interlock.
Set to “1” when Interlock signal fault
OFF – DC Output OFF.
Set to “1” when the Power Supply DC
output is OFF.
SO – Shut OFF (Daisy In).
Set to “1” when Shut OFF signal is high.
OVP – Over Voltage Protection.
Set to “1” when Over Voltage Protection
fault occurs.
FLD – Foldback.
Set to “1” when Foldback fault occurs.
OTP – Over Temperature Protection.
Set to “1” when Over Temperature
Protection fault occurs.
AC – AC.
Set to “1” when AC fault occurs.