EasyManua.ls Logo

TDK-Lambda G10-500 - Auxiliary Commands

TDK-Lambda G10-500
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
95
Model Rated Output
Voltage (V)
Minimum (V)
Maximum (V)
10 0.5 12
20 1.0 24
30
1.5
36
300 15 330.75
600 30 661.5
Table 5-6: OVP Programming Range
Model Rated Output
Voltage (V)
Minimum (V)
Maximum (V)
10 0 9.5
20 0 19
30 0 28.5
300
0
285
600 0 570
Table 5-7: UVL Programming Range
5.10.8 Auxiliary Commands
LANG SCPI
Function Set a communication protocol to the SCPI language.
The Power Supply addressing is lost after the communication language change.
RIE <Bool>
Function Enable / Disable ILC function. If disabled, Power Supply ignores the ILC pin
state.
Parameters
0|1, OFF|ON
Query
RIE?
Returns
<Bool> OFF|ON
PVS <DSC>
Function Set the Voltage programming source: Front Panel, External Resistor, or
External Voltage.
Parameters
0|1|2 or DIG|VOL|RES
Query
PVS?
Returns
<DSC> DIG|VOL|RES