EasyManua.ls Logo

TDK-Lambda G10-500 - Output Commands

TDK-Lambda G10-500
188 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90
RST
Function
Reset setting. Refer to Table 3-5.
Returns
<DSC> OK
\
Function Repeat last command. If \<CR> is received, the Power Supply will repeat the last
command
Returns
<DSC> OK
FRST
Function
Restore factory reset parameters. Refer to Table 3-5 & Table 3-6
Returns
None
NOTE:
Factory Reset does not affect advanced parallel configuration acknowledgment (does not affect
power supply configuration (Single, Master or Slave roles does not change).
5.10.6 Output Commands
PV <NR2>
Function
Set digital programming output voltage value in Volts
Parameters Range is limited by the Power Supply model, OVP and UVP settings. Refer to
Table 5-4
Query
PV?
Returns
<NR2> 5-digits format
MV?
Query
Returns a measured output voltage
Returns
<NR2> 5 digits format
PC <NR2>
Function
Set digital programming output current value in Amperes
Parameters
Range is limited by the Power Supply model. Refer to Table 5-5.
Query
PC?
Returns
<NR2> 5-digits format
MC?
Query
Returns a measured output current
Returns
<NR2> 5 digits format

Table of Contents