136
6.1.3.6 Step
Execute a single step from a sequence in the LIST or WAVE mode. Step function is available via
the Front Panel menu (refer to section 2.7) or via the communication command [PROGram]:STEP
<DSC>.
6.1.3.7 Abort
Stop sequencer WAVE or LIST mode execution. Return sequencer system to idle state. Abort
function is available via the Front Panel menu (refer to section 2.7) or via the communication
command ABORt.
NOTE
Consecutive ON -> OFF -> ON function via Front Panel or a command has 200 milli-seconds
delay. Therefore, it is recommended to program Power Supply output to 0 volts instead of OFF if
fast sequence is required.
NOTE
Refer to section 2.7
to operate the sequencer functions via the Front Panel. Refer to section
5.14.7 to operate the sequencer functions via communication commands.
NOTE
If sequencer system is in the INITIATED STATE (following the INIT command or INIT function via
the Front Panel), power supply does not accept additional WAVE or LIST
voltage/current/time/dwell parameters. Use the Abort command prior applying new parameters.
NOTE
If sequencer system is in the INITIATE STATE (following the INIT command or INIT function via
the front panel), power supply does not load previously stored sequences. Use the Abort
command prior applying new parameters.
NOTE
If the Sequencer function is enabled (INITIATE STATE), the Internal Resistance, Constant Power
Limit, Slew-Rate and Analog Programming functions are disabled.
NOTE
If the Internal Resistance, Constant Power Limit, Slew-Rate or Analog Programming functions are
enabled, the Sequencer function is disabled.