121
NOTE
SYSTem[:COMMunicate]:BOOL[:STATe] <DSC> command is available from firmware revision
02.110.
SYSTem[:COMMunicate]:INTerface <DSC>
Function Sets a communication interface.
Power supply addressing is lost after communication interface change.
Parameters
0|1|2|3|4, RS232|RS485|LAN|USB|OPTion
Query
SYSTem[:COMMunicate]:INTerface?
Return
<DSC> RS232, RS485, LAN, USB, OPT
NOTE
Execution time for this command is ~25mS
SYSTem[:COMMunicate]:LAN:HOST?
Query
Reads hostname. LAN specific command.
Return
<SRD> up to 15 characters long
Example
G10-500-<X>
NOTES
<X> represents a running number (1, 2, 3, etc…) according to the number of Power Supplies from
the same type.
A number is added only if at least 2 Power Supplies of the same type are connected to the same
network.
SYSTem[:COMMunicate]:LAN:IDLED <Bool>
Function
Blink Display & green LXI LED. LAN specific command.
Parameters
0|1, OFF|ON
SYSTem[:COMMunicate]:LAN:IP <SRD>
Function
Sets a LAN IP address. LAN specific command.
Parameters
xxx.xxx.xxx.xxx
Query
SYSTem[:COMMunicate]:LAN:IP?
Return
<SRD> xxx.xxx.xxx.xxx
Example
192.200.0.10; 192.9.33.110 (No zeros padding)
SYSTem[:COMMunicate]:LAN:MAC?
Query
SYSTem[:COMMunicate]:LAN:MAC? LAN specific command.
Return
<SRD> xx:xx:xx:xx:xx:xx (hexa-decimal)
Example
A0:12:34:FF:01:6D
SYSTem[:COMMunicate]:LAN:RESet
Function Sets LAN parameters to default.
Refer to LAN reset settings, Section 4.7.5.3.