Limit switch signal
This is the signal from the 2 limit switches which determine the machine’s range of up-down
motion. The lower microswitch is a NC contact input to the up-down board (pin 4-6 of
connector CN3). When this contact opens the circuit board inhibits movement in the down
direction. The upper microswitch is a NO contact input to the up-down board (pin 3-6 of
connector CN3). The upper microswitch is always pressed therefore it provides a NC contact.
When this contact opens the circuit board inhibits movement in the up direction.