6.10. THE DISPLAYED ELEVATION IS INCORRECT
The machine displays this error if there is a mismatch between the photocell model and the SW of
the up-down board or there is a bad photocell reading due to incorrect calibration, breakage or
disturbances produced by the motor brushes as a result of excessively high currents.
THE DISPLAYED
ELEVATION IS INCORRECT
Is the position of the limit switch
correct?
Is the up-down motor current correct?
YES
NO
YES
Lubricate the elev ation
bars
2
NO
Regolare la posizione dei
microswitch
Is the photocell clean?
Clean the photocell
YES
Replace the photocell and
cable RN-12Q connecting
the up-down board and
the photocell
NO
Are the elev ation bars lubricated?
NO
Replace the up-down
motor
YES
Is the SW of the up-down board
matching the photocell model?
NO
Install the proper v ersion
YES
1