Measure
3-46
TDS3000B Serie s User Manual
Measurement name Definition
Positive
Duty
Cycle
Measurement of the first cycle in the waveform.
Positive Duty Cycle =
Positive Width
Period
× 100%
Positive
Overshoot
Measured over the entire waveform.
Positive Overshoot =
Max–High
Amplitude
× 100%
Positive
Width
Measurement of the first positive pulse in the
waveform. The time between the 50% amplitude
points.
Rise Time Time that the leading edge of the first pulse in the
waveform takes to rise from 10% to 90% of its
amplitude.
RMS The true Root Mean Square voltage over the entire
waveform.
Snapshot All
Measurements
Displays all measurement values (except two-chan-
nel measurements) at the time you pushed the
Snapshot All Measurements button, for the
selected waveform. Push the Snapshot A ll
Measurements button to update the list values.
Push the MENU OFF button to clear the list from
the screen.