Audio Performance Verification Procedures
Audio Perform
ance Verification Procedures
Required Equipment
Table 67: Re
quired Test Equipment (Audio)
Generates the following signals: Tektronix TG 2000 with the following
modules:
WFM7120/WFM7020 with option HD:
1080i 59.9
4 100% color bars with two or
more groups of embedded audio
HDVG1 module for TG2000
SDI serial digital video test generator with
embedded audio
All instruments with SD:
525/270 100% color bars w ith two or
more gro
ups of embedded audio
DVG1 module for TG2000
Sine wav
e generator
Capable
of 0.8 Vp-p at 6 MHz into a
50 Ω load
Rohde & S
chwarz SMT03 Opt. SM-B2
Test Oscilloscope Amplitude measurements of a 6 Mhz sine
wave
Tektronix TDS7404B
Analog/Digital audio generator/analyzer
35 kHz to 96 kHz sample rate range, jitter
measurement per AES-3 (1997)
Rohde & Schwarz UPL06 O pt B22, B29
Precision 75 Ω -to-50 Ω adapter 1.5% impedance and attenuation
accu
racy
Tektronix AMT75
75 Ω c
oaxial cables (2 required)
Gene
ral purpose digital video
Male-to-male BNC connectors 3’
long
Belden 8281
50 Ω coaxial cables (2 required) Male-to-male BNC connectors 36 inches
lon
g
Tektronix part number 012-0482-00
75
Ω terminator
Male connector Tektronix part number: 011-0055-02
Audio test cable
1/
4 inch phono to 2 XLR
So
und Professionals SP-XLRM-MINI-1
with adapter SP-PHONE-MINI-ST
A
udio breakout cable
DB62 to XLR I/O required for Audio
Options AD and DDE
T
ektronix part number 012-1688-00
Calculator Logarithmic function
Dolby (R) digital audio generator Generates Dolby D and Dolby E bit
streams
Required for Option DDE
Dolby Laboratories DM100
120 Waveform Monitors Specifications and Performance Verifi cation