Test Records
Table 60: WFM7120 Waveform Monitor Audio Option DS Test Record (cont.)
Performance Test Minimum Incoming Outgoing Maximum
AES Audio Output Amplitude
AESB1-2I/O
0.9 v 1.1 v
AESB3-4I/O
0.9 v 1.1 v
AESB5-6I/O
0.9 v 1.1 v
AESB7-8I/O
0.9 v 1.1 v
AES Audio Output Jitter
AESB1-2I/O
Pass
AESB3-4I/O
Pass
AESB5-6I/O
Pass
AESB7-8I/O
Pass
AES Audio Level Meter Accuracy Over Frequency
AESA1In(100Hz)
Pass
AESA2In(100Hz)
Pass
AESA3In(100Hz)
Pass
AESA4In(100Hz)
Pass
AESA5In(100Hz)
Pass
AESA6In(100Hz)
Pass
AESA7In(100Hz)
Pass
AESA8In(100Hz)
Pass
AESA1In(1kHz)
Pass
AESA2In(1kHz)
Pass
AESA3In(1kHz)
Pass
AESA4In(1kHz)
Pass
AESA5In(1kHz)
Pass
AESA6In(1kHz)
Pass
AESA7In(1kHz)
Pass
AESA8In(1kHz)
Pass
AESA1In(19kHz)
Pass
AESA2In(19kHz)
Pass
AESA3In(19kHz)
Pass
AESA4In(19kHz)
Pass
AESA5In(19kHz)
Pass
AESA6In(19kHz)
Pass
AESA7In(19kHz)
Pass
AESA8In(19kHz)
Pass
Headphone level accuracy over frequency
Left (100 Hz)
–0.75 dBu 1.25 dBu
56 Waveform Monitors Specifications and Performance Verification