70
Tempest900 2-Channel Operating Manual
Buttons on the BeltStation do not function
A number of buttons on the BeltStation can have alternate functions that the user can select.
If a button on the BeltStation is not working as expected, re-conrm all settings and any alternate function assignment in the menu. The button
may have been reassigned wirelessly from the BaseStation or by T-Desk. Conrm that the function is available for use. If the reassignment
involves any GPO, conrm that menu selection, the connections, and the equipment functionality.
Call Function does not work properly
Check to make sure that the CALL function is enabled.
Conrm that a TALK button is enabled for the channel that you wish to call.
A Call signal will be received by the BeltStation only on the channel(s) that are currently being monitored.
Stage Announce (SA) function does not work properly
The Stage button has two separate functions. Optionally, it controls the shared Stage relay contact on the back of the BaseStation.
When you press the STAGE button it reroutes the BeltStation user’s microphone to the SA output on the back of the BaseStation.
When pressing the STAGE button, if there is no audio present at the SA, conrm that the Stage Announce function is enabled in the
BeltStation.
If the SA relay does not close, ensure that the Stage Relay is enabled in the BeltStation. If problems persist, conrm the operation with
another BeltStation.
Tempest Remote Transceiver
Remote Transceiver RX or TX LEDs do not light
While the Transceiver is properly connected to the BaseStation, turn the BaseStation Power Switch to the OFF position. Wait for 30 seconds
and turn the BaseStation Power Switch back to the ON position. This should initialize the Remote Transceiver. The Cong LED should
light momentarily and then go out. Once the Cong LED goes out the Remote Transceiver TX LED should light. If there are BeltStations
communicating to the BaseStation through the Remote Transceiver the RX LED should light as well.
When connecting any shared BaseStations to any wired intercom system, only channels
connected to the wired system can be shared. A BeltStation CALL signal is sent only
when the Talk button is enabled.
To manually re-initialize the Transceiver, power OFF the BaseStation for at least 15 seconds
and power the BaseStation back ON, with the Transceiver connected.