4 Operation
TC29
32
4.2 Engine
4.2.1 Starting the engine
Before placing the machine into
operation, the inspections outlined in
Chapter 7.7 must be carried out each
time.
Before starting the engine, take care to
ensure that no one is in the immediate
vicinity of the machine or in the danger
zone.
All gearshift levers to neutral.
Insert ignition key in pre-heat/starter switch
(11/34).
Turn clockwise to "1"; indicator lamps (11/18,
11/20) light up.
Pre-heating starts; control light (11/19) lights
up.
In the event of a cold start, the throttle
handle must be fully open. Reduce
the throttle when the engine is
running smoothly!
After the control light (11/19) has gone out, turn
the pre-heat/starter switch to "2". As soon as
the engine is running, turn the ignition key to "1"
and decrease the revs to low idle speed.
Control lights must go out.
If the engine has not started after max. 30 sec.,
turn the ignition key to "1" or "O", and wait for at
least 1 minute before trying again. Repeat the
start-up procedure.
If the engine has not started after 2 start-up
procedures, determine the source of the fault.
Do not drive the engine at full throttle
straight away. Drive with restraint until
the operating temperature of the engine
has been reached.
Fig. 11-Operation