Maintenance and care 7
TW85 81
Changing coolant
Only open the radiator cap when the
engine is cold. There is danger of
scalding when checking hot coolant!
Park the machine on level ground.
Turn off the engine and allow the cooling
system to cool.
Remove the cooler cap (59/1).
Unscrew the water-drain plug (61/1) on the
cylinder block and drain coolant.
Remove the bottom water hose from the cooler
and drain coolant.
If necessary, flush the cooling system with
clean water.
Re-fit the drain plug to the engine and the water
hose.
Fill the cooling system with coolant (see
Technical data section 3.9) and close the cap.
Start the engine and bring to operating
temperature; turn off the engine and allow to
cool.
Check the coolant level and top up (several
times, if necessary).
1
HR32-046
Figure 61 Engine block