7 Maintenance and care
86 TW85
7.9.5.3 Cartridge replacement
Main cartridge
Release the wire tighteners (69/1) and remove
the bottom of the housing (69/4).
Withdraw the main cartridge (69/2) by twisting
slightly to and fro.
Check whether the safety cartridge (69/3) must
be replaced.
Remove the safety cartridge only in
the case of necessary maintenance
work. Only open the seal (69/5) of
the safety cartridge for the purpose
of replacement.
Note down the date of maintenance in the
appropriate sections of the safety cartridge
(69/3).
Insert the new or cleaned main cartridge
carefully into the filter housing starting with the
open side and check that it is correctly
positioned.
Fit the lower part of the housing. (Pay attention
to the position of the dust ejection valve)
Place the wire fasteners in the groove of the
flange on the filter housing and tighten
Safety cartridge
Remove the main cartridge.
Do not clean the safety cartridge and,
once it has been removed, do not
use it again.
Using a suitable tool (e.g. screwdriver), pierce
the seal (69/5) of the safety cartridge (69/3)
from the inside, then lift up the two clips (69/6).
Grasp the safety cartridge (69/3) by the two
clips (69/6), withdraw by moving slightly to and
fro, and dispose of it.
Insert a new safety cartridge and check that it is
correctly positioned.
Re-install the main cartridge.
3
2
1
4
5
6
HM32-068
3.
2.
1.
Fig. 69 Air filter