E.4 Basic operating steps ..................................................................19
E.4.1 Switching the measuring instrument on ....................................19
E.4.2 Calling up the function ............................................................20
E.4.3 Entering values ........................................................................20
E.4.4 Printing data ............................................................................21
E.4.5 Saving data ..............................................................................21
E.4.6 Confirming an error message ..................................................21
E.4.7 Switching the measuring instrument off ....................................21
E.5 Memory ......................................................................................22
E.5.1 Folders ....................................................................................22
E.5.2 Location ..................................................................................23
E.5.3 Protocols ................................................................................24
E.5.4 Extras Memory ........................................................................25
E.6 Instrument diagnosis ..................................................................26
F. Configuration ......................................................................................26
F.1 Instrument settings ......................................................................27
F.1.1 Display edit ..............................................................................27
F.1.2 Printer ......................................................................................28
F.1.3 Start keys edit ..........................................................................29
F.1.4 AutoOff ....................................................................................29
F.1.5 Communication ........................................................................30
F.1.6 Date/Time ..............................................................................30
F.1.7 Language ................................................................................30
F.2 Sensor settings ............................................................................31
F.3 Fuels ..........................................................................................35
G. Measuring ............................................................................................36
G.1 Preparing measurements ............................................................36
G.1.1 Zeroing phases ........................................................................36
G.1.2 Using the modular flue gas probe ............................................37
G.1.3 Configuring the reading display ................................................37
G.1.4 Set location/fuel ......................................................................37
G.2.1 Flue gas, Flue gas + m/s, Flue gas + Dp2 ................................38
G.2.2 Program ..................................................................................39
G.2.3 Draught ....................................................................................40
G.2.4 Smoke#/HCT ..........................................................................40
G.2.5 Gas flow rate ..........................................................................41
G.2.6 Oil flow rate ..............................................................................42
G.2.7 m/s ..........................................................................................42
G.2.8 Dp2 ........................................................................................43
G.2.9 Burner control ..........................................................................43
Content
5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO 340 and is the answer not in the manual?

TESTO 340 Specifications

General IconGeneral
CO measurement range0 to 10, 000 ppm
NO measurement range0 to 3, 000 ppm
NO2 measurement range0 to 500 ppm
SO2 measurement range0 to 5, 000 ppm
Resolution CO1 ppm
Resolution NO1 ppm
Resolution SO21 ppm
Resolution H21 ppm
Resolution Differential Pressure0.01 hPa
Resolution Flow Velocity0.1 m/s
Resolution Temperature0.1 °C
Power SupplyRechargeable battery
Protection ClassIP40
Measurement ParametersO2, CO, NO, NO2, SO2, CO2, CxHy, Temperature, Draft, Pressure
O2 measurement range0 to 25%
Temperature measurement range-20 to 1, 200 °C
Resolution CO20.1%
Accuracy CO±5 ppm or ±5% of reading
Accuracy NO±5 ppm or ±5% of reading
Accuracy NO2±5 ppm or ±5% of reading
Accuracy SO2±5 ppm or ±5% of reading
Accuracy O2±0.2%
Accuracy CO2±0.5%
Accuracy H2±5 ppm
Accuracy Differential Pressure±0.03 hPa
Accuracy Temperature±0.5 °C
DisplayLCD
Operating Temperature-5 to +45 °C
Storage Temperature-20 to +50 °C