29
UNIT OPERATING INSTRUCTIONS PREMIUM HMI CONTROLLER
Single Temperature
• All bulkheads should be taken down to
create one large compartment.
• Turn all zones on.
• Set all zones to the same setpoint.
Contact your Dealer aout our “Drivers Guide
to Simple operation” for more details on
operating the unit display.
STARTING THE DIESEL ENGINE
Diesel engine preheats and starts are automatic
in both Continuous Mode and
CYCLE-SENTRY Mode. The engine will
preheat and start as required when the unit is
turned on. The engine preheat and start will be
delayed in CYCLE-SENTRY mode if there is
no current need for the engine to run. If any
keys are being pressed on the HMI control
panel the engine will not preheat and start until
10 seconds after the last key is pressed
Note: If the unit is equipped with optional
Electric Standby there may be some
additional prompts before the engine will
start. See STARTING THE ELECTRIC
MOTOR on the following pages for details.
CAUTION: The engine may start
automatically any time the unit is turned on.
WARNING: Never use starting fluid.
When the engine is preparing to start the HMI
control panel will display the engine start
screen, as shown in Figure . The preheat
buzzer sounds during the engine preheat and
crank sequence.
Engine Start Screen
After the engine is started the display returns to
the Standard Display of temperature and
setpoint.
STARTING THE ELECTRIC MOTOR
Units equipped with the Electric Standby
option only.
Electric motor starting is automatic in both
Continuous Mode and CYCLE-SENTRY
Mode. The motor will start as required when
the unit is turned on. If any keys are being
pressed on the HMI control panel prior to the
motor start, the motor start will be delayed until
10 seconds after the last key is pressed.
CAUTION: The motor may start automatically
any time the unit is turned on.
When the motor is preparing to start the HMI
control panel will display the motor start
screen, as shown in Figure below. The preheat
buzzer sounds for 20 seconds before the
electric motor starts.
Motor Start Screen
After the motor is running the display returns to
the Standard Display of temperature and
setpoint.