UNIT OPERATING INSTRUCTIONS PREMIUM HMI CONTROLLER
SELECTING SLEEP MODE
Normal CYCLE-SENTRY mode starts and
stops the unit as required to maintain the
desired setpoint temperature, maintain the unit
battery in a charged condition and keep the unit
engine warm in cold ambient conditions. Sleep
mode does not consider setpoint or maintain
cargo temperatures - it only keeps the engine
warm and the unit battery charged. This is
useful in extremely cold weather or when the
unit is to be out of service for an extended time.
Sleep mode operates in both Diesel mode and
Electric mode. In Diesel mode the unit will
start and stop as required to maintain engine
temperature and battery charge. In Electric
mode the unit starts and stops as necessary to
maintain battery charge only.
When Sleep mode is entered, the operator can
program an automatic Wake-up Time up to a
week away. Using this feature, the unit will
automatically restart and run normally at the
determined time. If a Wake-up Time is
programmed the operator can also program an
automatic Pretrip Test when the unit restarts.
Sleep Mode is turned On and Off using the
Mode Menu. From the Standard Display, press
the MENU key. (Figure "Menu Key" page 29)
The Language Menu or Alarm Menu will
appear. Press the NEXT key as required to
show the Mode Menu. When the Mode Menu
is shown press the SELECT key.
Select Key
Press the Next key as required to display the
Sleep Mode prompt. Press the Select key to
choose the Sleep Mode menu.
Sleep Mode Menu
The screen shown will appear.
Start of Sleep Mode Menu
The operator can now choose a Sleep Mode
Wake-up Time or simply enter Sleep Mode
immediately. If NO is pressed the unit will
immediately enter Sleep Mode.
Select No to Enter Sleep Mode
The display will show SLEEP and the unit will
start and stop as required to keep the engine
warm and/or the battery charged. Sleep mode
does not consider setpoint or maintain cargo
temperatures. To exit Sleep Mode press the
EXIT key or turn the unit off and back on. The
unit will resume normal operation and control
to setpoint.
Sleep Mode Display

Table of Contents

Other manuals for Thermo King T- series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King T- series and is the answer not in the manual?

Thermo King T- series Specifications

General IconGeneral
RefrigerantR-404A
Voltage12V/24V DC
DefrostElectric or Hot Gas
ModelT-series
Cooling CapacityVaries by model
Power SourceDiesel Engine or Electric
Temperature Range-29°C to 24°C
Control SystemMicroprocessor-based
Fuel Tank CapacityVaries by model
DimensionsVaries by model
WeightVaries by model