47
TSR/TSR-3 ALARM CODES
24 Heating Cycle
Fault
The indicated zone is
not longer able to
operate and has
been shut down.
25 Alternator Check If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
26 Check
Refrigeration
Capacity
Manually monitor
load temperature.
Report alarm at end
of the day.
28 Pretrip or Self
Check Abort
Report alarm at end
of the day.
29 Defrost Damper
Circuit Check
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
30 Defrost Damper
Stuck
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
31 Check Oil
Pressure Switch
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
Code Description Operator Help
32 Refrigeration
Capacity Low
The indicated zone is
not longer able to
operate and has
been shut down.
Repair immediately.
33 Check Engine
RPM
Report alarm at end
of the day.
34 Check Modulation
circuit
Manually monitor
temperature. Report
alarm at the end of
the day.
35 Check Run Relay
Circuit
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
36 Electric Motor
Failed to Run
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
37 Check Engine
Coolant Level
Report alarm at end
of the day.
38 Electric Phase
Reversed
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
Code Description Operator Help
39 Check Water
Valve Circuit
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
40 Check High
Speed Circuit
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
41 Check Engine
Coolant
Temperature
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
42 Unit Forced to
Low Speed
Report alarm at end
of the day.
43 Unit Forced to
Low Speed
Modulation
Report alarm at end
of the day.
44 Check Fuel
System
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
45 Hot Gas or Hot
Gas Bypass
Circuit
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
Code Description Operator Help

Table of Contents

Other manuals for Thermo King T- series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King T- series and is the answer not in the manual?

Thermo King T- series Specifications

General IconGeneral
RefrigerantR-404A
Voltage12V/24V DC
DefrostElectric or Hot Gas
ModelT-series
Cooling CapacityVaries by model
Power SourceDiesel Engine or Electric
Temperature Range-29°C to 24°C
Control SystemMicroprocessor-based
Fuel Tank CapacityVaries by model
DimensionsVaries by model
WeightVaries by model