TSR/TSR-3 ALARM CODES
141 Autoswitch Diesel
to Electric
Disabled
Report alarm at end
of the day.
143 Check remote
drain hose heater
o/p (zone)
Report alarm at end
of the day.
144 Lost CAN
communications
to expansion
module
Unit cannot operate,
needs to be repaired
immediately
145 Loss of Controller
"On" Feedback
Signal
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
146 Software Version
Mismatch
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
147 Check Multitemp
fan speed control
o/p (zone)
Manually monitor
load temperature.
Report alarm at end
of the day.
148 Autoswitch
Electric to Diesel
Disabled
Report alarm at end
of the day.
149 Alarm Not
Identified
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
Code Description Operator Help
150 Out of Range Low Manually monitor
load temperature.
Report alarm at end
of the day.
151 Out of Range
High
Manually monitor
load temperature.
Report alarm at end
of the day.
153 Expansion
module flashload
failure
Report alarm at end
of the day.
154 Low suction
pressure switch
failure
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
155 Lost CAN
communications
to HMI
Unit cannot operate
and needs to be
repaired immediately
156 Check suction/
liquid heat
exchanger bypass
valve
If unit is shut down
repair immediately.
Otherwise, report
alarm at end of the
day.
157 Optiset plus
profile mismatch
Report alarm at end
of the day.
159 Check battery
connection
Report alarm at end
of the day.
160 Lost CAN
communications
to Radio
Expansion board
Report alarm at end
of the day.
Code Description Operator Help
163 Emission control
failure
203 Check Display
Return Air Sensor
Manually monitor
load temperature.
Report alarm at end
of the day.
204 Check Display
Discharge Air
Sensor
Manually monitor
load temperature.
Report alarm at end
of the day.
233 REB transitioning
from conservative
to Full Null
Report alarm at end
of the day.
234 Check relative
humidity sensor
Report alarm at end
of the day.
251 Check radio
expansion board
configuration
Report alarm at end
of the day.
252 Check Auto Fresh
air exchange
circuit
Report alarm at end
of the day.
254 Check auxilary Report alarm at end
of the day.
Code Description Operator Help

Table of Contents

Other manuals for Thermo King T- series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thermo King T- series and is the answer not in the manual?

Thermo King T- series Specifications

General IconGeneral
RefrigerantR-404A
Voltage12V/24V DC
DefrostElectric or Hot Gas
ModelT-series
Cooling CapacityVaries by model
Power SourceDiesel Engine or Electric
Temperature Range-29°C to 24°C
Control SystemMicroprocessor-based
Fuel Tank CapacityVaries by model
DimensionsVaries by model
WeightVaries by model

Related product manuals