Document Ref 941113-001 Rev 2 Page 6-7
Quantium 310 Maintenance Manual Maintenance Procedures - VR
21) Feed the motor control cable up the unit, through the gland and into the calculator head.
Replace cable ties and tighten the relevant gland.
Note : ensure that the cable is routed and contained accordingly.
22) Using the small screwdriver, re-connect the motor control cables (positive and negative)
to the ECVR circuit board.
Note : refer to the wiring diagram in section 7.
23) Feed the motor power cable up the unit, through the gland and into the junction box.
Replace the cable ties and tighten the relevant gland.
Note : ensure that the cable is routed and contained accordingly.
24) Using the small screwdriver, re-connect the motor power cable in the junction box.
Note : refer to the wiring diagram in section 7.
25) Using the 6mm allen key, re-fit the junction box cover.
26) Ensure that all tools and unused materials are removed.
27) Secure the side panel to the dispenser.
28) Close the calculator head door and lock.
29) Re-fit the hydraulic doors to the dispenser and lock.
30) Re-instate power to the dispenser.
31) Test the operation of the new motor.
32) Dispose of all waste accordingly.