2-2 Tolomatic User Guide: ICR Rod Style Integrated Control Actuator
2 : ICR SV1B BASIC - ELECTRICAL INTERFACE, SPECS & WIRING
2.1.2 I/O Cables and Pin-outs
CABLE TOLOMATIC
PART NO.
CONNECTOR ON
ACTUATOR
MATING CONNECTOR*
ON CABLE
I/O: Std., 5 meter 3604-1640 Norcomp: 171-025-103L001 Norcomp: 171-025-203L001
I/O: IP65, 5 meter 3604-1648 Amphenol: PT02E16-26P(027) Amphenol: PT06E16-26S(476)
* This type of mating connection is used on Tolomatic supplied cables. Reference this type of mating connector
for customer designed cables.
PIN NUMBERS
STD. IP65 DESCRIPTION CABLE WIRE COLOR
TECHNICAL INFO.
PAGE NO.
1 A
2 B
3 C
4 D
5 E
6 F
7 G
8 H
9 J Enable Orange/Black
2-5
10 K E Stop Red/White
11 L
12 M Extend Command Blue/White
2-513 N Input Common White/Black/Red
14 P Retract Command White/Red
15 R
16 S
17 T
18 U In Position Output Green/Black/White
2-7
19 V Ground** Green/Black
20 W Fault Output Black/White/Red
21 X Ground** Black/White
22 Y +24 V Brake Power Input Red/Black
2-8
23 Z Ground** Black/Red
24 a +24 V Keep Alive Red
2-9
25 b Ground** Black
** Signal grounds not needed for operation. Grounds on signal connector are common to ground or power
connector. It is recommended to leave thee unconnected unless specifically required for the application.