Tolomatic User Guide: ICR Rod Style Integrated Control Actuator 4-3
4.1.3 Suggested Power Supplies:
Switching Power Supply: Lambda SWS600-48
Unregulated Power Supply: International Power IP500U36
Bus Fuse: 15 Amp, 125V or equivalent or sized for application
Logic Power Fuse: 2 Amp, 125V or equivalent
Figure 4-2: Unregulated Power Supply Configuration with Shunt Regulator
Figure 4-3: Regulated Power Supply Configuration with Blocking Diode and Added
Capacitance
Figure 4-4: Regulated Power Supply with Blocking Diode and Shunt Regulator
POWER SUPPLY RECOMMENDATIONS : 4
+24-48VDC POWER
POWER GROUND
CASE / SHIELD GROUND
KEEP ALIVE
REGULATED
POWER SUPPLY
24 to 48VDC
+
-
DIODE
CAPACITOR
FUSE
E-STOP
FUSE
+24-48VDC POWER
POWER GROUND
CASE / SHIELD GROUND
KEEP ALIVE
REGULATED
POWER SUPPLY
24 to 48VDC
+
-
DIODE
SHUNT
REGULATOR
FUSE
E-STOP
FUSE
+24-48VDC POWER
POWER GROUND
CASE / SHIELD GROUND
KEEP ALIVE
UNREGULATED
POWER SUPPLY
24 to 48VDC
SHUNT
REGULATOR
FUSE
E-STOP
FUSE
+
-