6-8 Tolomatic User Guide: ICR Rod Style Integrated Control Actuator
6 : HOW TO USE THE ICR/ICM SV1P PLUS ACTUATOR
6.8.2 Analog Command
The ICR Plus actuator can be driven by an analog voltage signal through the Analog
Command input. The amplifier can convert the signal to a current (torque), velocity
or position mode. When using the ICR Plus actuator, select the position operating
mode. The encoder on the ICR Plus is not exposed through the connectors and
requires a factory modification in order to utilize the current and velocity mode
scaling parameters. Contact Tolomatic if current or velocity modes of operation
are required.
To program the ICR Plus actuator using the analog input as the command source:
1. In the Basic Setup screen, navigate to the Operating Mode Options screen.
2. Select Position for the Operating Mode.
3. Select Analog for the Command Source.
Figure 6-9: CME 2
®
Basic Setup Operating Mode for Analog Command Source
4. Refer to the CME 2
®
User Guide, Section 7.1: Analog Command Settings
supplied on the CD-ROM shipped with the ICR Plus actuator for complete
information on using the analog command setting parameters.