Tolomatic User Guide: ICR Rod Style Integrated Control Actuator 2-7
ICR SV1B BASIC - ELECTRICAL INTERFACE, SPECS & WIRING : 2
2.3 Digital Outputs – ICR SV1B Basic Actuator
The ICR SV1B Basic actuator has 3 digital outputs, 2 of them are implemented. The
outputs are both sinking and sourcing and are protected against over current and
short circuit conditions. Once an over current condition is present, the output turns
off until the load is removed. The power is generated internally.
Figure 2-11: ICR SV1B Basic Actuator Output Interface Circuit Diagram
ICR SV1B Basic Actuator Digital Output Specifications
Output high minimum (10 mA source), 24 V power 20 V
Output low maximum (10 mA sink) 2 V
Maximum continuous current 20 mA
Fold back current 85 mA
Maximum output sink / source voltage 24 V
Update rate 2 ms
ICR SV1B Basic Actuator Digital Output Functionality
SIGNAL NAME DESCRIPTION
In Position Output will go high when the actuator is not moving.
Fault Output will go high when an error is present.
The spare and any designated outputs can be programmed at Tolomatic for custom
applications. Please consult Tolomatic for custom applications.
10
10
33
+24VDC
OUTPUT