26. SPECIFICATIONS
166
Guide Light
Light source LED (red 626 nm/green 524 nm)
Distance 1.3 to 150m
*1
Visible range Right and Left/Upward and Downward:± 4° (7m/100m)
Resolving power at center area (width)
4’ (about 0.12/100m)
Brightness 3 levels (bright/normal/dim)
Internal memory
Capacity 500 MB (includes memory for program files)
External memory
USB flash memory (up to 8 GB)
Data transfer
Data input/output Asynchoronous serial, RS232C compatible
USB USB Ver. 1.1, Host (Type A) and Client (Type miniB)
Handle (Remote Control System Beam Detector)
Operable range (Slope distance when using RC-5R under normal atmospheric conditions
*1
)
Standard mode 2
*15
to 100 m
*16
Far mode 2
*15
to 250 m
*17
2
*15
to 300 m
*16
Maximum detecting area (vertical angle)
±30° (on the basis of horizontal direction)
Remote Control System Turning operation time (RC-5R)
About 15 sec (until completion of rapid (single) measurement)
*15 : When there is almost no vertical interval between instrument height and the target height, the
instrument height is 1.5 m, target height is 0.10 m at a horizontal distance of 1.8 m
*16 : When the vertical interval between PS and the beam emitter of Remote Controller is no more
than 20 m
*17 : When the vertical interval between PS and the beam emitter of Remote Controller is no more
than 40 m
Bluetooth wireless communication (option)
Transmission method FHSS
Modulation GFSK
Frequency band 2.402 to 2.48GHz
Bluetooth profile SPP, DUN
Power class Class 1
Usable range to 600m (good communication condition)
*18
to 300m (normal communication condition)
*19
Authentication Yes/No (selectable)
*18 : Paired with RC-5R, with instrument height to be more than 1.5m, no obstacles (like building
structures, trees or vehicles) causing interrupting/reflecting radio wave, few sources of radio
emissions/interference in the near vicinity of the instrument, no rain
*19 : Paired with RC-5R, located at a general residential/urban area, few sources of radio