60
11.MEASUREMENT WITH AUTO TRACKING
With the Auto Tracking function, the instrument searches for and sights the target. The instrument will
then following that target as it is moved from measurement point to measurement point. The Remote
Control System is recommended for high performance Auto Tracking measurement.
C Caution
The instrument emits a laser beam during Auto Pointing and Auto Tracking operation.
G
Auto Pointing model does not support Auto Tracking.
Auto Tracking can only be performed when a prism is used as the target. Auto Tracking is not
possible with reflective sheet and reflectorless measurement.
Use designated reflective prisms for higher precision measurement.
C"24. PRISM System"
If more than one prism is located in the field of sight during Auto Tracking, an operation error will
occur and the instrument will not be able to find the target.
The instrument cannot perform Auto Pointing/Auto Tracking when there is glass between the
instrument and the prism. A measurement error will occur.
If an obstacle blocks the laser beam path between the instrument and the prism, instrument cannot
find the target correctly.
PROCEDURE
1. Select "Motor" in <Configuration>.
Select the Configuration tab.
Set "Track Setting" to "Track".
11.1 Auto Tracking Settings