EasyManua.ls Logo

Topcon PS Series - Page 96

Topcon PS Series
183 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15. RESECTION MEASUREMENT
90
4. Sight the first known point and press [MEAS] to
begin measurement.
The measurement results are displayed on the
screen.
5. If measuring two or more known points, repeat
procedures 4 in the same way from the second
point.
6. Press [CALC] or [YES] to automatically start
calculations after observations of all known points
are completed.
Instrument station elevation and standard
deviation, which describes the measurement
accuracy, are displayed in the "Result" tab.
Standard deviation values for each point are
displayed in the "Detail" tab.

Table of Contents

Related product manuals