Theslotinthecam,aftersetting9onthecam,allowsthe
impellergatetobeopenedtothemaximumposition.This
settingcanbeusedfordrysand,icemelt,orothermaterials
thataredifculttospread.
Note:Usecamsetting9maywhenyouarecleaningoutthe
hopper.
SprayerControls
Figure13
1.Sprayer-pressurecontrol5.Sprayerwand
2.Tank-agitationlever
6.Sprayer-pressuregauge
3.Narrow-spraypatternlever
7.Sprayer-pumpswitch
4.Wide-spraypatternlever8.Wandpressurecontrol
SprayerPressureControl
Thesprayer-pressurecontrolislocatedonthecontrolconsole
(Figure13).
•Rotatethesprayer-pressurecontrolclockwisetoincrease
thepressuretothesprayernozzles
•Rotatethepressure-controlcounterclockwisetothe
decreasenozzlepressure.
TankAgitationLever
Thetank-agitationleverislocatedonthecontrolconsole
(Figure13).
Settingthetank-agitationlevertotheONpositionallowsthe
sprayerpumptocirculatethecontentinthespraytankin
ordertokeepthechemicalsolutionmixed.
•Pullthetank-agitationleverrearwardtocirculatethe
contentinthespraytank.
•Pushtheleverforwardtostopcirculatingthecontent
inthespraytank.
Note:Agitationisnotmeanttobeusedwhilespraying.
Shutoffthetankagitationtoensureproperspray
distribution.
Note:Runtheenginespeedaboveidleandrunthesprayer
pumpforthetankagitationtoworkeffectively.
Narrow-SprayPatternLever
Thenarrow-spraypatternleverislocatedonthecontrol
console(Figure13).
•Pullthenarrow-spraypatternlevertowardyoutoturnon
thesprayerinanarrow-spraypattern(thecenternozzle
only).
•Pushthenarrow-spraypatternleverawayfromyouto
turnoffthesprayer.
Wide-SprayPatternLever
Thewide-spraypatternleverislocatedonthecontrolconsole
(Figure13).
•Pullthewide-spraypatternlevertowardyoutoturnON
thesprayerinawide-spraypattern(therightandleft
nozzles).
•Pushthewide-spraypatternleverawayfromyoutoturn
OFFthesprayer.
Sprayer-PressureGauge
Thesprayer-pressuregaugeislocatedonthecontrolconsole
(Figure13).
Usethepressuregaugetoseetheuidpressureinthesprayer
system.
Sprayer-PumpSwitch
Thesprayer-pumpswitchislocatedonthecontrolconsole
(Figure13).
Usethesprayer-pumpswitchtostartandstopthepump
whensprayingorcirculatingtheuidinthesprayertank.
•Pushdownonthetopofthesprayer-pumpswitchto
startthepump.
•Pushdownonthebottomoftheswitchtostopthepump.
Spray-WandTriggerandTriggerLock
Thespray-wandtriggerandtriggerlockarelocatedonthe
bottomofthespray-wandhandle(Figure13andFigure14).
•Tousethespraywand,holdthehandleofthewand
squeezethetrigger.
•TolockthetriggertotheONposition,fullysqueezethe
triggeragainstthehandleandthenlatchthetriggerlock
overthetrigger;tounlockthetrigger,unlatchthetrigger
lockfromthetrigger.
•Releasethetriggertostopthespray.
18